Main Topic: Data Center Fixes as Recommended from AI To Police Itself?
Dear Diary. Artificial intelligence has rapidly become a part of our lives, but there is currently a big backlash against it because associated data centers are detrimental to our climate due to more burning of fossil fuels and to the environment in general. This week the Nvidia scandal rocked all seats of power in the United States. Evidentially, the company is too big to fail, so Trump intervened to put its CEO, Jesen Huang, back in charge, making the stock market soar back to levels before his board removed him. Besides, Trump had invested in Nvidia, so he wanted the company not to fail; thus, there appears to be corrupt inside trading here.
I don’t think that we should throw out the proverbial baby with the bathwater, though. Datacenters can be fixed if companies that build them make the proper investment without cutting corners. Also, it’s my opinion that AI is not out to get us. Personally, I found that it is a useful tool. So, I asked AI to write an eight-page essay about how it would fix itself that is fairly technical. If you don’t agree with what it wrote to defend itself, let me know.
Here is that article:
Building Cleaner, Quieter, More Energy-Efficient Data Centers
A technical assessment of power, pollution, cooling, water, acoustics, and climate impacts
Guy on Climate | November 25, 2026
The Data Center Boom Has an Environmental Cost
Data centers are becoming a critical part of modern infrastructure. They support communications, medical research, financial transactions, weather forecasting, scientific modeling, and increasingly the training and operation of artificial intelligence. Yet a building full of computers is also an industrial energy installation. Nearly all the electricity entering its processors and supporting equipment eventually becomes heat. That heat must be removed continuously, often with considerable demand for electricity, water, and noisy mechanical equipment. Backup generators add another potential source of air pollution.
The expansion is fast enough to matter for climate policy. The International Energy Agency (IEA) estimates that data centers consumed approximately 485 terawatt-hours (TWh) of electricity worldwide in 2025 and projects about 950 TWh in 2030 in its central scenario, around 3% of global electricity demand. These are estimates and projections, not a measured future outcome. [1] For the United States, Lawrence Berkeley National Laboratory’s 2025 update estimates that data centers could account for approximately 11.8% of national electricity use by 2030. Actual demand will depend on investment, computing efficiency, electricity prices, and deployment rates. [2]
The challenge is not to pretend that useful computation can be made impact-free. It is to design facilities that deliver more useful computing with fewer kilowatt-hours, fewer tons of greenhouse gases, less water stress, less toxic exhaust, and less unwanted noise. These are separate performance questions. A data center with exceptionally efficient cooling can still be a major source of emissions if powered by fossil-fueled electricity. A carbon-free facility can still waste water or disturb neighbors. Environmental success therefore requires an engineering approach that measures and improves all of these dimensions together.
Measure the Right Things Before Claiming to Be Green
The best-known efficiency metric is power usage effectiveness, or PUE:
PUE = Total facility electricity / IT equipment electricity.
If servers, storage, and networking equipment consume 100 megawatts (MW), and the whole facility draws 125 MW, PUE is 1.25. The extra 25 MW supports cooling, pumps, fans, power conversion, lighting, and other overhead. A hypothetical facility moving from PUE 1.60 to 1.20 at the same constant 100 MW IT load saves 40 MW, or roughly 350 gigawatt-hours per year at full-year operation. This is an illustrative calculation, not a claim about any particular center. The U.S. Department of Energy and ASHRAE recommend fundamental air-management and power-system improvements that can reduce such overhead. [3][4]
PUE alone, however, cannot say whether software is efficient. If a facility doubles the number of wasteful computing jobs, it can maintain an excellent PUE while doubling energy consumption. Operators should also report energy per completed task—such as kilowatt-hours per thousand model inferences, per training run, per transaction, or per petabyte processed—while describing workload complexity and quality. These units are not always directly comparable across services, so the denominator must be transparent.
Water usage effectiveness (WUE) normally expresses on-site water consumption in liters per kilowatt-hour of IT electricity. Carbon intensity should be reported in kilograms of carbon dioxide equivalent per kilowatt-hour and, where defensible, per unit of computing work. Energy reuse factor (ERF) describes the portion of energy supplied to a facility that is beneficially reused outside it. European reporting rules have begun to formalize PUE, WUE, and energy-reuse reporting. [5]
The critical distinction is between annual averages and time-specific impacts. A company may buy renewable electricity credits equivalent to its annual electricity consumption while operating through hours when the local grid relies heavily on fossil fuels. Reporting both location-based emissions and contractual market-based emissions, together with hourly carbon-free electricity matching and estimates of marginal grid impacts, gives a more meaningful picture than a single claim of being “100% renewable.” Independent measurement and public disclosure should be standard practice.
Start With the Computers: Less Work per Answer
The first opportunity is inside the computing equipment itself. Servers that spend much of their time idle still draw electricity for memory, networking, fans, power supplies, and other components. Better utilization, consolidation of lightly loaded machines, and automatic shutdown of unused capacity can reduce the electrical baseline. Virtualization and container scheduling let operators pack compatible work onto fewer active hosts, although concentrating loads can create thermal hot spots that cooling designers must anticipate.
Chip selection matters enormously. Graphics processors and specialized accelerators can perform suitable AI and scientific workloads more efficiently than general-purpose processors, but their advantage depends on actual utilization. Buying faster chips is not automatically a climate benefit if the lower cost per computation produces vastly more computation overall. Operators should evaluate energy per useful result, not just peak operations per second or nominal accelerator efficiency.
At the software level, efficient algorithms, smaller task-appropriate models, lower numerical precision where accuracy permits, caching, batching, inference routing, retrieval instead of repeated generation, and early termination of unnecessary computation can reduce demand. An oversized AI model should not be used for a simple classification task when a smaller one produces a sufficiently accurate answer. Model quantization and sparsity can reduce memory transfers and arithmetic, but effects depend on hardware and workload. Designers should verify real wall-plug energy savings rather than assuming theoretical floating-point savings translate directly into reduced facility consumption.
Storage and data movement also matter. Repeatedly transferring large datasets across facilities consumes electricity in switches, optical links, storage systems, and associated cooling. Locating frequently used data close to processors, eliminating duplicate datasets, using compression sensibly, and setting retention policies can reduce unnecessary activity. For nonurgent jobs, carbon-aware scheduling can shift some computing to hours or grid regions with cleaner available electricity, provided the shift does not increase transmission burdens, local congestion, or total workload enough to cancel the gain. The guiding principle is simple: avoid wasteful computation before constructing more generation to support it.
Cooling Technology: From Airflow to Warm-Water Liquid Loops
Cooling is the most visible source of facility overhead. Conventional air cooling moves large volumes of air through server racks and into computer-room air handlers. Poorly arranged rooms mix hot exhaust with cool supply air, forcing fans and refrigeration equipment to work harder. Hot-aisle/cold-aisle layouts, physical containment, properly sealed floor openings, unobstructed cable paths, and variable-speed fan controls can substantially reduce this waste. ENERGY STAR and ASHRAE describe these as core efficiency measures. [4][6]
Setpoints must be based on equipment inlet requirements, not a belief that server rooms should feel cold to people. ASHRAE’s widely used recommended inlet range for many air-cooled equipment classes is 18–27°C, subject to humidity, altitude, and equipment-specific limits. [7] Raising supply temperatures within verified operating specifications can permit more hours of economizer operation, when outdoor conditions provide sufficient cooling without full mechanical refrigeration. In dry and temperate climates, air-side or water-side economizers may greatly reduce compressor runtime; in hot and humid climates, their advantages are more limited. Filtration, air quality, corrosion, and moisture control also influence the design.
Dense AI racks increasingly exceed the heat flux that can be handled economically by conventional room air systems alone. Direct-to-chip liquid cooling circulates a coolant through cold plates attached to processors and sometimes memory components. A coolant distribution unit and heat exchangers transfer the collected heat to a separate facility loop. Immersion cooling places suitable electronics in a dielectric fluid. Liquid systems can transport concentrated heat with far less air movement, but they introduce pumps, fittings, leak-detection requirements, compatibility questions, and potentially expensive retrofits. They should be evaluated through whole-system efficiency and reliability, not as a universal cure. [4]
One of the most promising designs uses relatively warm liquid loops to transfer heat outdoors without mechanical chillers for more hours of the year. Depending on ambient conditions and component requirements, dry coolers, adiabatic heat rejection, or hybrid systems can remove heat without relying on a constantly operating compressor. Heat-pump and heat-exchanger performance, pressure drop, approach temperature, and seasonal operating data must be modeled hour by hour. A design that is excellent in Finland may perform poorly during a Georgia heat wave.
Almost every electrical watt used by the IT equipment becomes thermal energy. A 100 MW IT installation therefore imposes approximately 100 MW of processor-related heat load, plus additional heat from supporting systems. The correct engineering question is not whether this heat can be eliminated, but how to remove or use it with the least added environmental cost.
Water Conservation Requires a Local Climate Calculation
There is a genuine water–energy tradeoff. Evaporative cooling towers can reject heat efficiently because vaporizing water removes large amounts of latent heat. They can reduce electrical demand relative to some dry cooling systems, especially during hot weather. However, they consume water through evaporation and blowdown. In a drought-prone basin, that demand can conflict with municipal and agricultural needs. Dry cooling substantially reduces direct water consumption, but its electricity use may increase during extreme heat. Closed-loop liquid cooling inside the data hall does not necessarily mean that the outdoor heat-rejection system is water-free. [8]
Water-use assessments should separate withdrawals from consumption, distinguish potable from reclaimed water, identify seasonal peak demands, and account for the water used to generate purchased electricity. A low on-site WUE can conceal significant off-site water consumption if its power supply depends on water-intensive generation. Conversely, a wet cooling system in a water-abundant region, supplied with treated reclaimed wastewater and clean electricity, may have lower overall environmental costs than a nominally water-free design elsewhere.
Useful technologies include recirculating cooling loops, drift eliminators, carefully controlled water chemistry, improved cycles of concentration where water quality permits, leak detection, nonpotable supply, dry or hybrid heat rejection, and weather-aware control systems. Developers should publish water budgets for extreme drought years, not simply annual averages. Given warming temperatures, historic climate normals may underestimate future heat waves and cooling peaks. In meteorological terms, engineers should test the proposed system against future plausible distributions of wet-bulb and dry-bulb temperatures rather than designing only for the recent mean.
Cleaner Electricity, Smarter Grids, and the Carbon Problem
Reducing PUE and IT demand limits the amount of power a facility needs. The next question is how that electricity is generated. Grid-supplied emissions depend on the mix of natural gas, coal, nuclear, wind, solar, hydroelectric, and other resources operating during each hour. A new large load can induce fossil-fuel generation during high-demand periods even when the buyer purchases annual renewable-energy certificates. Lower-carbon operation is more credible when electricity procurement creates additional clean supply and matches consumption closely in time and location.
A practical package combines long-term clean-energy contracts, hourly carbon-free electricity accounting, energy storage, grid-responsive computing, and attention to transmission capacity. Solar and wind can supply substantial energy, but variability makes storage, demand flexibility, geographic diversification, dispatchable low-carbon generation, and improved grids important. Batteries are especially useful for short outages, peak shaving, rapid load changes, and shifting electricity across hours. They do not automatically provide economical multi-day backup for a large campus. The IEA has highlighted how rapidly changing AI power demand and grid bottlenecks complicate supply planning. [1]
On-site natural-gas turbines or engines are sometimes proposed as a way to bypass delays in grid connections. They can improve resilience but should not be labeled clean merely because their carbon dioxide emissions per kilowatt-hour may be lower than those of older coal plants. They still emit carbon dioxide and nitrogen oxides, and upstream methane leakage increases climate impact. Hydrogen-ready branding does not establish low emissions today; the hydrogen’s production pathway and verified methane or hydrogen leakage rates matter.
A high-quality siting study should model not only the average regional grid mix but also the marginal effect of adding hundreds of megawatts at a specific substation. Locating new installations where low-carbon generation and transmission are available can reduce climate impacts and the chance of raising local electricity costs. Grid agreements should disclose who pays for transmission upgrades, reserve capacity, and reliability measures. Communities should not unknowingly subsidize a large private electric load.
Backup Generators: Air Pollution Is Not an Emergency-Only Issue
Data centers often use banks of diesel generators so servers can keep operating during power interruptions. Diesel combustion produces carbon dioxide, nitrogen oxides (NOx), particulate matter, and other pollutants. NOx contributes to ground-level ozone and secondary particle formation, while diesel particulates can affect respiratory and cardiovascular health. Pollution occurs during emergency operation but also during scheduled testing and maintenance. The U.S. Environmental Protection Agency and regional air districts treat these engines as regulated stationary emission sources. [9]
Better options include robust grid interconnections; appropriately sized battery-based uninterruptible power supplies; load shedding that preserves critical services while reducing unnecessary computation; selective use of cleaner backup technologies; and fewer generator test hours where safety, manufacturers, and regulations permit. Where diesel remains necessary, high-performance emissions controls, ultra-low-sulfur fuel, careful maintenance, continuous records of run hours, and strict air permits are essential. Backup systems should be evaluated against realistic multi-hour or multi-day outages, not merely the first few minutes of a grid failure.
Fuel cells may reduce local combustion pollutants depending on type and fuel, but fossil-gas-powered fuel cells still carry greenhouse-gas emissions and upstream methane concerns. Batteries eliminate local exhaust while discharging, yet their lifecycle emissions depend on battery production and charging electricity. The aim should be to reduce both local pollution and total lifecycle emissions, rather than swapping one metric for another.
A Quieter Data Center Is an Engineering Choice
Noise is a pollution problem too. Unlike intermittent construction work, cooling equipment often operates around the clock. Fans, air-cooled condensers, chillers, transformers, pumps, cooling towers, and periodic generator testing can generate an intrusive mixture of broadband sound, low-frequency hum, and distinct tones. At night, background noise decreases and persistent mechanical sound may become more noticeable. A facility that meets a simple daytime A-weighted decibel threshold may still disturb nearby homes through low-frequency or tonal components. Planning guidance increasingly recognizes these concerns. [10]
Acoustical mitigation should begin with site selection. The distance between equipment and residences, topography, building orientation, and the placement of exhaust outlets all influence exposure. Designers can use low-noise fan selections, larger slower-turning fans, variable-speed drives, resilient equipment mounts, vibration isolation, silencers on exhaust and air intakes, acoustic louvers, sound-attenuating enclosures, and properly engineered barriers. High-performance generator enclosures require sufficient ventilation and safe exhaust dispersion; acoustics cannot come at the expense of fire safety or engine reliability.
The relationship between sound and fan speed is not linear, and making a fan smaller and faster can worsen noise even where airflow is unchanged. Reducing pressure losses through better duct and coil design may allow lower fan rotational speeds, benefiting both energy use and acoustic performance. A facility should commission a predictive acoustical model before construction and verify it afterward at property boundaries and nearby residences. Measurement plans ought to include day and night conditions, A-weighted and where appropriate C-weighted sound levels, one-third-octave frequency bands, tonal penalties, and generator-test events. These metrics must be interpreted under applicable local ordinances; there is no single universal decibel limit suitable for every community.
Routine generator tests should be scheduled with public notice, preferably outside sensitive evening and nighttime hours, and integrated testing should be designed to minimize unnecessary runtime. Residents should have access to a complaint process and independently reviewable monitoring data. Treating neighbors as stakeholders at the permitting stage is more effective than installing expensive sound barriers after a project has opened.
Reuse Heat, but Count the Energy Honestly
Data centers reject immense quantities of low-grade heat. In cold climates, that heat can sometimes warm nearby buildings, greenhouses, or district-heating networks. Warm-water cooling loops improve the usefulness of recovered heat because they deliver heat at a higher temperature than typical room-air exhaust. Heat pumps can raise the temperature to levels needed by a district network, but they consume additional electricity and their seasonal coefficient of performance must be included in the accounting. [4]
Google’s Hamina facility in Finland is an example of a site incorporating seawater cooling and off-site heat recovery. [11] Such projects work best where there is a nearby year-round heat customer, suitable piping infrastructure, and an economically useful match between supply and demand. A data center may produce heat throughout the summer when the surrounding city needs little space heating, so seasonal mismatch matters. Thermal storage or industrial process heat uses can sometimes improve the match.
Heat recovery does not make the center’s electrical consumption disappear. It can avoid some separate fuel use in the community while requiring pumps, heat exchangers, and perhaps heat-pump electricity. The appropriate calculation compares the full energy systems with and without heat recovery, including emissions from displaced heating fuel. Developers should not subtract exported heat from electricity consumption when reporting PUE; separate energy-reuse indicators make the distinction transparent.
Lifecycle Emissions and a Public Accountability Standard
The environmental footprint starts before the first server is switched on. Construction materials such as steel, concrete, copper, and aluminum carry embodied emissions. Semiconductor fabrication, chip packaging, batteries, cooling hardware, and eventual disposal also create environmental costs. Replacing servers annually can improve operational efficiency but increase manufacturing emissions and electronic waste. A lifecycle assessment should compare emissions avoided during operation with the carbon cost of earlier replacement, using credible equipment lifetimes and local grid projections.
Climate-resilient design is equally important. Cooling capacity, transmission systems, flood protection, and backup power should withstand heat waves, storms, droughts, and wildfire smoke. A facility that is efficient during a typical spring day but fails or relies heavily on diesel during a record summer heat wave is not resilient. Developers should use projections of future extremes and document how rapidly their equipment derates during hotter conditions.
Governments can require environmental impact assessments and publicly accessible annual—and for selected metrics hourly—reporting. The European Union’s data center reporting framework provides one model for greater comparability, though local laws differ. [5] At minimum, useful disclosures should include facility and IT electricity; PUE; water withdrawal and consumption; WUE; grid electricity source and hourly emissions estimates; on-site combustion fuel and pollutant emissions; backup generator run hours; noise at nearby receptors; embodied carbon; and verified useful heat exports.
These measurements should be paired with safeguards for sensitive grid or security details, without allowing commercial confidentiality to become an excuse for hiding environmental impacts. Independent audits, permit enforcement, and consequences for repeated violations matter more than voluntary marketing statements. Environmental reporting should also state the absolute totals. A 20% reduction in energy per computation is not a climate victory if total power demand triples and the additional generation comes largely from fossil fuels.
A Practical Blueprint for the Next Decade
The least polluting data center is not defined by a single device or certification. It is a carefully located, well-metered facility that minimizes wasteful computing, uses appropriately sized efficient processors, manages airflow or liquid cooling intelligently, avoids unnecessary freshwater consumption, buys or enables truly low-carbon electricity, minimizes combustion backup, protects neighboring communities from noise, and finds useful outlets for waste heat where feasible.
For existing facilities, the first year should begin with submetering, an hourly electricity and water baseline, an acoustic survey, a software utilization audit, and a cooling-control review. Operators can then fix poorly contained airflow, idle servers, deficient fan controls, and unnecessary testing before undertaking major capital projects. The next stage may involve liquid-cooling retrofits, power distribution upgrades, clean-energy contracts, and water-system conversions. New projects should require integrated energy-water-noise-carbon modeling before land is purchased, rather than treating environmental mitigation as a late-stage permitting expense.
There is no reason to assume that better computing systems must inevitably become dirtier, louder, or thirstier. Engineers have numerous tools to lower each burden. But improvement per unit of computation must be distinguished from improvement in the real world. As artificial intelligence and other digital services expand, the climate test is whether absolute greenhouse-gas emissions fall, whether water withdrawals remain compatible with local ecosystems, and whether neighboring communities can live comfortably beside the infrastructure.
The lesson is similar to the larger climate challenge: efficiency is necessary, but efficiency alone is not enough. We must ask not only how much computation society can produce, but how cleanly and responsibly we choose to produce it.
Sources and technical references
[1] International Energy Agency, Key Questions on Energy and AI (2026), executive summary
https://www.iea.org/reports/key-questions-on-energy-and-ai/executive-summary
[2] Lawrence Berkeley National Laboratory, United States Data Center Energy Usage Report: 2025 Update
https://eta.lbl.gov/publications/united-states-data-center-energy-2025
[3] U.S. Department of Energy, Best Practices Guide for Energy-Efficient Data Center Design (2024)
https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design
[4] ASHRAE, Energy and Thermal Efficiency, AI Data Center Energy Performance Framework
https://ashrae.org/technical-resources/topics-and-initiatives/ai-data-center/energy-and-thermal-efficiency
[5] European Commission, Delegated Regulation (EU) 2024/1364 on data center reporting
https://eur-lex.europa.eu/eli/reg_del/2024/1364/oj
[6] ENERGY STAR, Manage Airflow for Cooling Efficiency
https://www.energystar.gov/products/data_center_equipment/16-more-ways-cut-energy-waste-data-center/manage-airflow-cooling-efficiency
[7] ASHRAE Handbook, Data Centers and Telecommunications Facilities: Environmental Classes
https://handbook.ashrae.org/Handbooks/A23/SI/A23_Ch20/A23_Ch20_si.aspx
[8] U.S. Department of Energy, Cooling Water Efficiency Opportunities for Federal Data Centers
https://www.energy.gov/cmei/femp/cooling-water-efficiency-opportunities-federal-data-centers
[9] U.S. Environmental Protection Agency, Clean Air Act Resources for Data Centers
https://www.epa.gov/stationary-sources-air-pollution/clean-air-act-resources-data-centers
[10] Chester County Planning Commission, Data Center Ordinance Guide (2026)
https://www.chescoplanning.org/UandI/DataCenters/pdf/DataCenterOrdinanceGuide.pdf
[11] Google Data Centers, Hamina, Finland: Cooling and Heat Recovery
https://www.datacenters.google/locations/hamina-finland/
Here are some “ETs” recorded from around North America the last couple of days, their consequences, and some extreme temperature outlooks, as well as any extreme precipitation reports:
Here is More Climate News from Wednesday:
(As usual, this will be a fluid post in which more information gets added during the day as it crosses my radar, crediting all who have put it on-line. Items will be archived on this site for posterity. In most instances click on the pictures of each tweet to see each article. The most noteworthy items will be listed first.)